Product Introduction
A company that understands the changes in the world and challenges the future through technological innovation.
BE THE BEST, BE THE FIRST

Low Voltage Motors
General Inverter Motors
- Product Description
-
Designed for centrifugal machinery like pumps and fans, these motors are intended for use in the operating speed range of 20~60Hz as self-ventilated types. They are designed to comply with energy utilization efficiency regulations according to the Energy Use Rationalization Act, Article 15, and are considered for minimum efficiency requirements.
- Product Features
-
Protection Method : Totally Enclosed Fan-cooled
Insulation Class : Class F or F/B
Protection Rating : IP44 or IP54/IP55
Cooling Method : Self-ventilated or Force-ventilated
Overload Capacity : 150% for 1 minute
What is an Inverter Motor?
It is a motor that can operate at any rotation speed through the input of variable voltage and frequency (AC), considering the cooling ability and mechanical strength according to speed changes. It is also designed to fully satisfy the speed-torque characteristics required by the load.
Considerations for Inverter Motors
Degradation Factors | Main Causes | Degradation Conditions |
---|---|---|
Thermal |
|
|
Electrical |
|
|
Environmental (Chemical) |
|
|
Mechanical |
|
|
The inverter-specific insulation system demonstrates excellent insulation performance against surge voltages.


Key Features
- ㆍExceptional Quality
- - Fast response to input signals
- - High torque for load adaptability
- - Long lifespan guaranteed by the application of an inverter-specific insulation system
- - Precision machining for reduced vibration
- - Harmonic reduction Core applied for lower noise
- ㆍHighest Reliability
- - Accumulated Know-how from the production of inverter-specific elevator motors (130,000 units)
- - Optimal technical compatibility with domestic and international inverters
- - Complete product range including vector, spindle, and servo motors for control applications
- ㆍSpecifications for Self-ventilated Type
-
General Specifications
- ㆍProtection Method: Totally Enclosed Fan-cooled
- ㆍInsulation Class: Class F or F/B
- ㆍProtection Rating: IP44 or IP54/IP55
- ㆍCooling Method: Self-ventilated or Force-ventilated
- ㆍOverload Capacity: 150% for 1 minute
- Additional details are available upon inquiry to select the appropriate specifications.
Appearance and Dimensions - Inverter Motor (Self-ventilated) Frame Size
출력 | 극수 | ||
---|---|---|---|
HP | kW | 4P | 6P |
1 | 0.75 | 80 | 90L |
2 | 1.5 | 90L | 100L |
3 | 2.2 | 112S | 112M |
5 | 3.7 | 112M | 132S |
7.5 | 5.5 | 132S | 132M |
10 | 7.5 | 132M | 160M |
15 | 11 | 160M | 160L |
20 | 15 | 160L | 180M |
25 | 18.5 | 180M | 180L |
30 | 22 | 180M | 180L |
출력 | 극수 | ||
---|---|---|---|
HP | kW | 4P | 6P |
40 | 30 | 200L | 200L |
50 | 37 | 200L | 225M |
60 | 45 | 225M | 250M |
75 | 55 | 225M | 250M |
100 | 75 | 250M | 280M |
125 | 95 | 280M | 280L |
150 | 110 | 280L | 315M |
175 | 132 | 315M | 315M |
200 | 150 | 315M | - |
- Specifications and appearances are subject to change without notice for product improvement.
Special Notes
- - The appearance and dimensions of self-ventilated inverter motors are identical to those of this catalog's three-phase, totally enclosed fan-cooled section.
- - If the primary operating frequency (speed) range is outside 40~70Hz, please consult the factory in advance for the selection of a motor specification more suitable for the load condition.