Quick Menu

Product Introduction

A company that understands the changes in the world and challenges the future through technological innovation.

BE THE BEST, BE THE FIRST

Low Voltage Motors

Vector Inverter Motors

Product Description

A type of inverter motor that can operate at any rotational speed through the input of variable voltage and frequency. It employs a speed sensor to separate the current into flux and torque currents for control and is fundamentally equipped with a forced cooling fan.

Product Features

Wide variable speed range

Capable of constant output operation at high speeds

Maintains low noise through frequency control

Excellent insulation performance

Outstanding delivery track record, wide variety of types

Application of Vector Inverter Motors
ㆍMain Uses of Vector Inverter Motors
Vector inverter motors are becoming increasingly applicable as their functions become more varied and precise. They are capable of replacing conventional power transmission and mechanical speed conversion devices. They are being adopted especially for loads requiring high starting torque, with an increasing trend of replacing DC and wound-rotor motors with vector inverter motors for their energy-saving effects and ease of maintenance and repair.
ㆍAdvantages of Vector Inverter Motors
- Wide variable speed range.
- Capable of constant output operation at high speeds.
- Capable of delivering sufficient torque even at low speeds, enabling continuous operation.
- Maintains low noise through frequency control.
Advantages of HIGEN Vector Inverter Motors
ㆍExcellent Insulation Performance
The application of high-speed switching devices such as IGBTs for inverter performance enhancement has increased high surge voltages and voltage rise rates (dt/dv), adversely affecting motor insulation. The vector inverter motor-specific insulation system complies with the voltage spikes regulation of NEMA MG-1 Part 31.
- Use of surge voltage-resistant magnet wire
- Varnish vacuum impregnation treatment
- Application of high dielectric strength insulation materials
- Increased insulation distance between charged and non-charged parts
ㆍHighest Quality, High Reliability
- Quick response to input signals
- High torque with good load response
- Longevity is assured by the application of an inverter-specific insulation system
- Stable torque characteristics across the entire range
- Precision machining for low-vibration
- Application of Harmonics reduction Core for low noise
- Optimal technical compatibility with domestic and international inverters
ㆍPrompt Delivery, Perfect Service
- Quick delivery response
- Customer technical support (seminars, technical briefings)
- Convenient nationwide distributor network
- Thorough after-sales service management
ㆍOutstanding Delivery Record, Wide Variety of Types
- The most extensive delivery record in Korea
- The complete product line of control motors, including vector, spindle, and servo motors
- Accumulated know-how from the production experience of elevator motors dedicated to inverters (130,000 units)
Motor Comparison (Including Drive Control)
Category DC Motor Wound Rotor Motor General Inverter Motor Vector Inverter Motor
Speed Control
Energy Saving Effect
Maintenance × ×
Price
Durability

※ ×: Poor / △: Average / ○: Good / ◉: Excellent

Vector Inverter Motor Characteristic Curves
Vector Inverter Motor Characteristic Curves
Category Rated Output (kW)
Continuous Rated Torque (kg · fm) Rotor GD2 (kg · f㎡)
Base Speed (rpm) Maximum Speed (rpm) Vibration / Noise Overload Capacity Accessories Other
4P 6P
4P 6P VX VY VX VY 4P 6P 4P 6P
0.75 0.41 0.63 0.04 0.04 0.05 0.05 1800 1200 3600 2400 Vibration V15

Noise Under 75dB(A)
Based on the VX Series

150% for 1 minute
Cooling Fan

Encoder

Overheat Protection Temperature Sensor (NTC)
Installation: Indoor

Altitude: Below 1000m

Ambient Temperature: -20 ~ +40℃
1.5 0.83 1.27 0.04 0.04 0.07 0.08
2.2 1.22 1.86 0.04 0.07 0.15 0.17
3.7 2.06 3.13 0.06 0.14 0.20 0.23
5.5 3.06 4.66 0.11 0.35 0.33 0.49
7.5 4.17 6.30 0.14 0.45 0.58 0.64
11 6.09 9.23 0.39 0.49 0.85 1.15
15 8.30 12.59 0.49 0.54 1.20 1.29
18.5 10.24 15.53 0.79 0.90 2.10 2.44
22 12.17 18.47 0.90 1.19 2.44 2.69
30 16.60 25.18 1.23 1.43 3.80 4.25
37 20.47 31.06 1.43 2.10 5.75 6.06
45 24.90 37.77 2.55 2.90 6.06 6.55
55 30.43 46.17 3.20 3.20 6.55 7.15
75 42.0 63.0 4.50 4.90 10.70 -
90 53.0 80.0 6.80 - 11.60 -
110 62.0 92.0 7.50 - 12.00 -
132 75.0 110.0 8.40 - 13.50 -
160 84.0 125.0 9.60 - 15.00 -
185 103.0 154.0 15.00 - 23.00 -

※ For environmental and operating conditions and options, please inquire separately with sales or the factory.

Vector Inverter External View (Horizontal Type)
FRAME NO. OUTPUT(kW) FIG.
NO.
DIMENSIONS(mm) WEIGHT(kg)
4P 6P BODY SHAFT 4P 6P
VX VY VX VY H L R E C B N K AB P F O A M G d ΦD T U W VX VY VX VY
112S 0.75
1.5
2.2
0.75 0.75 0.75 1 112 420 187 60 70 114 148 12 187 240 42 232 190 226 13 22 28j6 7 4 8 35 35 35 35
1.5 1.5
112M 3.7 2.2 2.2 1.5 1 112 449 200 60 70 140 172 12 187 240 42 232 190 226 13 22 28j6 7 4 8 45 45 45 45
132S 5.5 3.7 3.7 2.2 1 132 520 239 80 89 140 175 12 250 280 42 269 216 250 15 42 38k6z 8 5 10 70 - 65 72
132M 7.5 - 5.5 3.7 1 132 560 258 80 89 178 215 12 250 280 42 269 216 250 15 42 38k6z 8 5 10 85 85 80 88
160M 11 5.5 7.5 5.5 1 160 681 323 110 108 210 250 15 265 323 51 316 254 300 18 45 42k6 8 5 12 120 120 120 130
160L 15 7.5 11 7.5 140
11 1 160 723 345 110 108 254 300 15 265 323 51 316 254 300 18 45 42k6 8 5 12 145 145 140 150
15 160
180M 18.5 18.5 15 11 1 180 735 351.5 110 121 241 280 15 286 365 60 366 279 321 25 45 48k6 9 5.5 14 200 240 180 210
180L 22 22 18.5 15 1 180 763 370.5 110 121 279 318 15 286 365 60 366 279 321 25 45 55m6 10 6 16 240 255 250 250
200L 30 30 22 18.5 1 200 970 426 140 133 305 365 19 368 416 60 396 318 400 25 80 60m6 11 7 18 295 295 305 305
37 37 22 320 320 340
255M 45 45 30 30 2 225 1115 444.5 140 149 311 410 19 425 475 60 464 356 432 30 80 65m6 11 7 18 385 380 420 450
55 55 37 37 420 450 500
250M 75 75 45 45 2 250 1260 513.5 140 168 349 444 24 428 522 71 511 406 485 30 80 75m6 12 7.5 20 580 600 550 600
55 55 600 650
280S 90 - 75 - 2 280 1350 544 170 190 368 518 24 544 600 90 583 457 546 37 80 85m6 14 9 22 780 - 770 -
280S 90 - 75 - 3 280 1255 544 170 190 368 518 24 544 600 505 583 457 546 37 80 85m6 14 9 22 780 - 770 -
280L 110 90 800 - 800
860
-
132 - 110 - 2 280 1480 588.5 170 190 457 577 24 544 600 90 583 457 521 37 80 85m6 14 9 22 860
150 880
280L 110 90 800
860
-
132 - 110 - 3 280 1345 588.5 170 190 457 577 24 544 600 505 583 457 521 37 80 85m6 14 9 22 800 860
150
315M 185 - 132 - 4 315 1540 614.5 170 216 457 605 28 - 648 249 635 508 628 35 80 95m6 14 9 25 1130 - 1130 -
160 1150
315M 185 - 132 - 5 315 1445 614.5 170 216 457 605 28 - 648 505 635 508 628 35 80 95m6 14 9 25 1130 - 1130 -
160 1150
  • Specifications and appearances are subject to change without notice for product improvement.
  • 옵션사항에 따른 내용은 별도로 영업 또는 공장에 문의 바랍니다.
Vector Inverter External View (Flange Type)
FRAME NO. OUTPUT(kW) FIG.
NO.
DIMENSIONS(mm) WEIGHT(kg)
4P 6P BODY SHAFT 4P 6P
VX VY VX VY Fr.No L A B C E AB N M O P PB K d e ΦD T U W VX VY VX VY
FF215 0.75 0.75
1.5
0.75
1.5
0.75 1 112S 463 180j6 215 60 60 182 16 250 403 235 4 15 22 - 28j6 7 4 8 42 42 42 42
1.5
2.2
FF215 3.7 2.2 2.2 1.5 1 112M 486 180j6 215 60 60 182 16 250 426 235 4 15 22 - 28j6 7 4 8 52 48 52 52
FF265 5.5 3.7 3.7 2.2 1 132S 536 230j6 265 80 80 255 15 300 456 274 4 15 42 - 38k6 8 5 10 78 72 78 80
FF265 7.5 - 5.5 3.7 1 132M 576 230j6 265 80 80 255 15 300 496 274 4 15 42 - 38k6 8 5 10 92 - 92 94
FF300 11 5.5 7.5 5.5 1 160M 778 250j6 300 110 110 265 20 350 668 317 5 19 45 - 42k6 8 5 12 125 110 135 135
FF300 11 5.5 7.5 5.5 1 160M 778 250j6 300 110 110 265 20 350 668 317 5 19 45 - 42k6 8 5 12 125 110 135 135
FF300 15 7.5 11 7.5 1 160L 882 250j6 300 110 110 265 20 350 712 317 5 19 45 - 42k6 8 5 12 125 130 155 155
11 150
15 160
FF350 18.5 18.5 15 11 1 180M 862 300j6 350 110 110 286 20 395 752 365 5 19 45 - 48k6 9 5.5 14 205 205 215 215
FF350 22 22 18.5 15 1 180L 891 300j6 350 110 110 286 20 395 781 365 5 19 45 - 55m6 10 6 16 240 255 245 255
FF400 30 30 22 18.5 1 200L 950 350j6 400 110 110 368 21 450 840 384 5 19 80 - 60m6 11 7 18 300 325 300 310
37 37 22 325 345 310 345
FF400 45 45 30 30 1 225M 1145 350j6 400 140 140 425 21 450 1005 454 5 19 80 - 65m6 11 7 18 385 455 385 455
55 55 37 37 455 480 455 480
FF500 75 75 45 45 2 250M 1240 450j6 500 140 140 428 25 550 1017 510 5 19 80 - 75m6 12 7.5 20 535 585 555 555
55 55 605 605
FF500 90 - 75 - 2 280M 1380 450j6 500 170 170 528 25 560 1210 560 5 19 80 394 85m6 14 9 22 720 - 750 -
FF500 110 - 95 - 2 280M 1380 450j6 500 170 170 528 25 560 1210 560 5 19 80 394 85m6 14 9 22 720 - 750 -
FF500 110 - 95 - 2 280L 1430 450j6 500 170 170 528 25 560 1260 560 5 19 80 394 85m6 14 9 22 750 - 780 -
132 800 820
160 860 -
View More Related Products
Vector Inverter

Vector Inverter

Marine

Marine

Three-Phase Totally Enclosed Fan-Cooled Horizontal Type

Three-Phase Totally Enclosed Fan-Cooled Horizontal Type

Three-Phase Totally Enclosed Fan-Cooled Vertical Type

Three-Phase Totally Enclosed Fan-Cooled Vertical Type

Single Phase Horizontal Type

Single Phase Horizontal Type

Increased Safety Type

Increased Safety Type

Flameproof Type

Flameproof Type

Dust Ignition Proof

Dust Ignition Proof

General Inverter Motors

General Inverter Motors

Frameless Type

Frameless Type

Aluminum Frame Type

Aluminum Frame Type

Hydraulic UNIT

Hydraulic UNIT

Cooling Tower Use (AOC)

Cooling Tower Use (AOC)

Cooling Tower Use (FWP)

Cooling Tower Use (FWP)

Three-Phase Semi-Enclosed

Three-Phase Semi-Enclosed

Pole Changing

Pole Changing

Tunnel Smoke Extraction Motor (KS)

Tunnel Smoke Extraction Motor (KS)

Tunnel Smoke Extraction Motor (NEMA C-FACE)

Tunnel Smoke Extraction Motor (NEMA C-FACE)